Nimbus i-Care

IntraOperative Neurophysiological Monitoring device

Dedicated to surgeons for a daily use

The NIMBUS i-Care is an IntraOperative NeuroMonitoring (IONM) and NeuroStimulator device. It is dedicated to surgeons for daily use in the operating rooms, as well as for neurosurgery, otology and spine surgery.

Two modes are available: « Stimulation » and « Monitoring » with pre-determinated and personalized settings which ensure a quick start and secure use of the device by the medical staff.

See our following page on surgeries:

Brain NEUROSURGERY AND NEUROTOLOGY
 
  • Direct electrical stimulation: cortical and subcortical mapping
  • Cranial nerves monitoring: cerebellopontine angle surgery and skull base surgery (Schwannoma, Meningioma)
  • Facial nerve monitoring: mastoidectomy (cholesteatoma)

 

Neuronal PERIPHERAL AND SPINAL NERVES NEUROSURGERY
 
  • Peripheral nerves stimulation and location: neurotomy
  • Spinal roots simulation and monitoring: spasticity correction surgery: dorsal rhizotomy

 

Head HEAD AND NECK SURGERY
 
  • Facial nerve monitoring: parotid gland surgeries, mastoidectomy
  • Recurrent nerve monitoring: thyroid surgery, parathyroidectomy

 

spinal ORTHOPEDIC AND SPINE SURGERY
 
  • Pedicular screw insertion
  • Peripheral nerves stimulation: hand surgery

 

  • Touch screen and validation button
  • Intuitive and simple interface
  • Predefined settings for clinical indication or for personal sessions
  • EMG box can be positioned on the patient bed
  • Remote control for distance use

 

 

  • Continuous display of programmed parameters, delivered current intensity and measured current circuit impedance
  • Audible indicator that demonstrates the correct circulation of the stimulation current
  • Continuous adaptation of the delivered stimulation current regardless the measured impedance

 

 

  • EMG needles lead-off detection
  • Ability to identify and personalize EMG recording channels
  • Continuous monitoring with over eight EMG channels, latency and amplitude measurement
  • Detection and deletion of the stimulation artefact
  • Audible warnings for EMG signals
  • Easy to read graphics: EMG signal freezes when it exceeds the adjustable threshold

 

 

  • EMG curve recording, saving and data exportation by USB port to computer under PDF and CSV formats
  • Importation and saving of customized configurations
  • Continuous intensity setting from the sterile zone via remote control or via touch screen
  • Modification of each setting: current intensity, current waveform, pulse duration, frequency range, burst duration and inter stimulus interval (burst mode)

 

  Medical device: class IIa
Monitoring Up to 8 monitoring channels (EMG)
Current intensity range 0 - 16 mA (32 mA peak to peak)
Current Waveform Rectangular biphasic or monophasic signals
Choice of the polarity for the first phase
Pulse duration range 60 – 16000 µs
Frequency range 1-800Hz
Eport of EMG curves USB port
Dimensions 36.5*28*27cm
Weight 10.5kg

 

 

Before using the device, please carefully read the instructions from the Nimbus i-Care user manual.