InnoScan 710-IR

InnoScan 710 INFRARED Micro Array Scanner

Technology

Confocal detection

  • Optimize fluorescence detection
  • Assure good focalization all along the scan
  • Less background
  • SNR is increased by 2.5 times

Real-time autofocus

  • Detection idone through a spatial phinhole
  • Follows the slide movement and deformation in real time during the scan
  • Avoid all out-of-focus signal

Automatic barcode reader

  • Reliable and traceable results

All standard microscope slides format

  • Glass
  • Nitrocelluose coated glass
  • Plastic
  • Silicon wafer
  • Gold coated glass

Dynamic range

  • From > 104 to >106
  • Detect the lowest signals avoiding saturation.

Technical specifications

InnoScan 710 IR

PIXEL SIZE3 - 40μm
LASER EXCITATION WAVELENGTH670nm785nm
COMPATIBLE FLUOROPHORES*Alexa Fluor 700, Alexa Fluor 680 DyLight 680, IRDye 680Alexa Fluor 790, DyLight 800, IRDye 800
LASER POWERAdjustable (2 laser powers)
LOADER CAPACITY1 slide
DETECTION TYPEReal-time confocal with 2 photomultipliers (PMT)
PMT GAINAdjustable from 0 to 100%
(Linear from 1 to 100%)
OPTICAL FILTER1 standard fluorescent filter by detection channel
FOCUSReal-time autofocus
Manual focus: offset adjustment 300 μm range, 1 μm increment
SLIDE SIZECompatible with all standard microscope slides: 25-26 x 75-76 mm2 / 1” x 3” ; thickness: 0.9 - 1.2 mm
SCANNING AREAAdjustable up to 22 x 74 mm2
SCANNING SPEEDFrom 10 to 35 lines/second (l/s)
3.6 minutes per slide at a resolution of 10 μm/pixel for a simultaneous two-color acquisition
DYNAMIC RANGE> 104 in normal mode or > 106 in dynamic extension mode
UNIFORMITY> 95%
BARCODE READERAutomatic barcode reading
INTERFACEEthernet interface
IMAGE FORMATTIFF (16-bit and 20-bit in dynamic extension mode)
POWER SUPPLY~ 100-240 VAC, 1.2 A, 50-60 Hz
ACQUISITION SOFTWAREMAPIX (image acquisition and spot quantification software)
DIMENSIONS (LXDXH)278 x 457 x 369 mm3 10.8” x 18.0” x 14.5”
WEIGHT15.5 kg (34.2 lbs)

InnoScan 710 IR AL

LOADER CAPACITY24 slides
DIMENSIONS (LXDXH)322 x 656 x 439 mm3 - 12.7” x 25.8” x 17.3”
WEIGHT31 kg (62 lbs)

* Non exhaustive list, please contact us for more information about fluorophore compatibility
Please contact us for any additional information.

Class I laser product for research use only
Specifications subject to change without notice
Contact us for the most recent specifications

Applications Notes

Publications

Applications

Protein detection by fluorescence-labelled antibodies on tissue sections is a widely used technique for the biomarker screening in complex diseases such as cancer to define biomarker expression on tumor cells and its distribution on a defined tissue.
Reverse Phase Protein Arrays (RPPA), also named cell lysate arrays, have been shown to be a useful tool for biomarker evaluation in large patient cohorts.