InnoScan 710-IR

InnoScan 710 INFRARED Microarray Scanners

InnoScan 710-ir - infrared microarray scanner

EASE OF USE, SPEED AND IMAGE QUALITY
Characterised by its ease-of-use, speed and image quality, InnoScan 710-IR infrared microarray scanner is the ideal tool for routine microarray reading.

Speed
With its patented XY motorisation, the InnoScan 710-IR is the fastest scanner on the market with adjustable reading speed from 10 to 35 lines per second (capable of scanning slides at 10 μm/pixel in less than 4 minutes).

Reliable and traceable results
With a barcode reader, InnoScan 710-IR microarray scanner provides accurate control of acquired images. InnoScan 710-IR is supplied with a validation slide and associated Mapix software that verifies scanner performance.

Routine use
InnoScan 710-IR is a low cost, portable scanner capable of reading medium density microarrays at a maximum resolution of 3 µm/pixel.

Technology

Microarray scanners laser confocal

Confocal detection

  • Optimize fluorescence detection
  • Assure good focalization all along the scan
  • Less background
  • SNR is increased by 2.5 times
Microarray scanners laser autofocus

Real-time autofocus

  • Detection idone through a spatial phinhole
  • Follows the slide movement and deformation in real time during the scan
  • Avoid all out-of-focus signal
Microarray scanners laser barcode

Automatic barcode reader

  • Reliable and traceable results
Microarray scanners laser slides

All standard microscope slides format

  • Glass
  • Nitrocelluose coated glass
  • Plastic
  • Silicon wafer
  • Gold coated glass
Microarray scanners dynamic range

Dynamic range

  • From > 104 to >106
  • Detect the lowest signals avoiding saturation.

Technical specifications

InnoScan 710 IR

PIXEL SIZE3 - 40μm
LASER EXCITATION WAVELENGTH670nm785nm
COMPATIBLE FLUOROPHORES*Alexa Fluor 700, Alexa Fluor 680 DyLight 680, IRDye 680Alexa Fluor 790, DyLight 800, IRDye 800
LASER POWERAdjustable (2 laser powers)
LOADER CAPACITY1 slide
DETECTION TYPEReal-time confocal with 2 photomultipliers (PMT)
PMT GAINAdjustable from 0 to 100%
(Linear from 1 to 100%)
OPTICAL FILTER1 standard fluorescent filter by detection channel
FOCUSReal-time autofocus
Manual focus: offset adjustment 300 μm range, 1 μm increment
SLIDE SIZECompatible with all standard microscope slides: 25-26 x 75-76 mm2 / 1” x 3” ; thickness: 0.9 - 1.2 mm
SCANNING AREAAdjustable up to 22 x 74 mm2
SCANNING SPEEDFrom 10 to 35 lines/second (l/s)
3.6 minutes per slide at a resolution of 10 μm/pixel for a simultaneous two-color acquisition
DYNAMIC RANGE> 104 in normal mode or > 106 in dynamic extension mode
UNIFORMITY> 95%
BARCODE READERAutomatic barcode reading
INTERFACEEthernet interface
IMAGE FORMATTIFF (16-bit and 20-bit in dynamic extension mode)
POWER SUPPLY~ 100-240 VAC, 1.2 A, 50-60 Hz
ACQUISITION SOFTWAREMAPIX (image acquisition and spot quantification software)
DIMENSIONS (LXDXH)278 x 457 x 369 mm3 10.8” x 18.0” x 14.5”
WEIGHT15.5 kg (34.2 lbs)

InnoScan 710 IR AL

LOADER CAPACITY24 slides
DIMENSIONS (LXDXH)322 x 656 x 439 mm3 - 12.7” x 25.8” x 17.3”
WEIGHT31 kg (62 lbs)

* Non exhaustive list, please contact us for more information about fluorophore compatibility
Please contact us for any additional information.

Class I laser product for research use only
Specifications subject to change without notice
Contact us for the most recent specifications

Applications Notes

Publications

Applications

Viruses, bacteria and parasites can cause deleterious diseases requiring rapid and efficient detection and therapeutic tools. Emerging infectious diseases with little known mechanisms of infection and pathogenicity represent a big challenge for research and clinics. 
Reverse Phase Protein Arrays (RPPA), also named cell lysate arrays, have been shown to be a useful tool for biomarker evaluation in large patient cohorts.